XY-WJ01 One-way Relay Module Delayed Power Off Disconnect Trigger Delay Cycle Timing Circuit Switch
- Stock: In Stock
- Brand: xcluma
- Model: BE-002356
- Weight: 44.00g
- SKU: BE-002356
- MPN: BE-002356
Rs572.00
(GST +18%Extra)
XY-WJ01 One-way Relay Module Delayed Power Off Disconnect Trigger Delay Cycle Timing Circuit Switch
Module highlights:
1. With LCD display, the current mode and parameters are clear at a glance, very clear, simple and practical;
2. Support key trigger control, high and low level trigger, switch value control, suitable for most occasions;
3. Wide voltage power supply (6 ~ 30V), very convenient to use;
4. Support UART data upload and parameter setting;
5. There is a key pause function, with reverse connection protection, reverse connection does not burn;
6. Added sleep mode. After enabling, there will be no operation for about 5 minutes, the LCD backlight will be turned off automatically; any key will wake up;
7. Different OP, CL, LOP parameters can be set, these parameters are independent of each other and saved separately;
8. All setting parameters are automatically saved after power off.
Operating mode:
P0: After the signal is triggered, the relay turns on the OP time and then turns off; within the OP time, the signal is invalid again when it is triggered
P1: After the signal is triggered, the relay turns on the OP time and then turns off; within the OP time, the signal triggers again to re-time
P2: After the signal is triggered, the relay turns on the OP time and then turns off; within the OP time, the signal triggers the reset again, the relay turns off and stops timing
P3: After the signal is triggered, the relay is turned off for CL time, and then the relay is turned on;
P4: Give the trigger signal, after the relay is turned on for OP time, the relay turns off the CL time, then cycle the above action, give the signal again in the cycle, restore the initial state, stop the timing; the number of cycles (LOP) can be set; the end of the cycle, the relay is maintained disconnect;
P5: Give the trigger signal, after the relay turns off the CL time, the relay turns on the OP time, then cycle the above action, give the signal again in the cycle, restore the initial state, stop the timing; the number of cycles (LOP) can be set; the end of the cycle, the relay Turn on;
P6: No trigger signal is required after power-on, the relay is turned on for OP time, the relay is turned off for CL time, and the above actions are repeated; the number of cycles (LOP) can be set; the end of the cycle, keep the relay open;
P7: No trigger signal is required after power-on. The relay is turned off for CL time, the relay is turned on for OP time, and the above actions are repeated. The number of cycles (LOP) can be set; the end of the cycle keeps the relay on;
P8: signal hold function If there is a trigger signal, the timing is cleared and the relay remains on; when the signal disappears, the relay is disconnected after timing OP; during the timing, there is a signal and the timing is cleared;
P9: signal hold function If there is a trigger signal, the timing is cleared and the relay remains open; when the signal disappears, the relay is turned on after timing CL; during the timing, there is a signal and the timing is cleared;
(P0 ~ P7) mode, short press the Pause button, the system starts timing when the system has not triggered the timing; when the system is already timing, the system pauses the timing, the relay is disconnected, and "OUT" is displayed as a flash to remind;
In P8 P9 mode, the pause button is used as the trigger signal in the running interface, and its button function is invalid when short press / long press;
Product parameters:
1: Working voltage: 6-30V power supply
2: Trigger signal source: high level trigger (3.0V ~ 24V), low level trigger (0.0V ~ 0.2V), switch value control (passive switch).
3: Output capability: can control devices within 30v 10A DC or within 220v5A AC
4: Quiescent current: 15mA Working current: 50mA
5: Service life: more than 100,000 times; working temperature: -40-85 ° C; weight: 45g, size: 7.1 * 3.9 * 2.5cm (length, width, height)
6: With optocoupler isolation, enhanced anti-interference ability, industrial-grade circuit board, setting parameters will always be remembered after power off.
Timing range:
0.01 seconds (minimum) to 9999 minutes (maximum) continuously adjustable
How to choose the timing range:
In the OP / CL parameter modification interface, short press the pause button to select the timing range;
XXXX without decimal point, timing range 1 second ~ 9999 seconds
The decimal point of XXX.X is in ten digits, and the timing range is 0.1 second to 999.9 second
XX.XX has a decimal point in the hundreds place, and the timing range is 0.01 second to 99.99 seconds
X.X.X.X decimal point is all on, timing range is 1 minute ~ 9999 minutes
For example, if you want to set the OP to 3.2 seconds, then move the decimal point to ten digits, and the LCD displays 003.2
Parameter description: OP on time, CL off time, LOP cycle times (1-9999 times, "----" means infinite cycles)
First, parameter settings
a) Press and hold the setting button to enter the setting interface;
b) First set the working mode, the working mode flashes to remind, set the working mode by short pressing the increase / decrease button;
c) Short press the setting button, select the working mode, and enter the system parameter setting;
d) In the system parameter setting interface, short press the setting key to switch the system parameter to be modified, short press / long press the increase / decrease key to modify;
(Note: short press setting button in P0 ~ P3 / P8 / P9 mode is invalid);
e) In the OP / CL parameter modification interface, short press the pause button to switch the timing unit (1s / 0.1s / 0.01s / 1min);
f) After all parameter settings are completed, press and hold the setting button to save the parameter settings and exit the setting interface;
Additional features:
a) Auto sleep function: In the operation interface (P0 ~ P7 mode), press and hold the pause button to enable or disable the auto sleep function (LP selected to start the sleep function, about five minutes without any operation, the LCD backlight automatically turns off , The system is running normally, any button wakes up; off turns off the sleep function);
b) Parameter view: In the operation interface, short press the SET key to display the current parameter settings of the system without affecting the normal operation of the system;
c) Display content switching: In P4 ~ P7 mode, press the DOWN key to switch the display content (running time / cycle times);