Menu
Your Cart

DC 5V-30V Dual MOS Controller Delay Timer with LED Digital

DC 5V-30V Dual MOS Controller Delay Timer with LED Digital
  • Stock: Out Of Stock
  • Brand: xcluma
  • Model: BE-002528
  • Weight: 18.00g
  • SKU: BE-002528
  • MPN: BE-002528
Rs287.00
(GST +18%Extra)

 

Description

·         Working voltage: DC5V-DC30V (wide voltage anti-connection protection)

·         Trigger signal source: high-level trigger DC 3.0V—24V signal ground and system ground to improve the system's anti-interference ability can also short-circuit the ground

·         Output capacity: DC DC 5V--36V, continuous current 15A at normal temperature, power 400W Under the condition of auxiliary heat dissipation, the maximum current can reach 30A

·         Mounting hole: diameter 3mm,Working temperature: -40 ° C ~ 85 ° C

Operating Mode:
• P1 mode: After the signal is triggered, the MOS transistor turns on the OP time and then turns off; in the OP time, the following operation
• P1.1: The signal is triggered again.
• P1.2: Signal triggers re-timed again
• P1.3: The signal triggers reset again, the MOS tube is disconnected, and the timing is stopped.
• P-2: Give the trigger signal, after the MOS transistor is disconnected from the CL time, the MOS transistor turns on the OP time. After the timing is completed, the MOS transistor is disconnected.
• P3.1: Give the trigger signal, after the MOS transistor turns on the OP time, the MOS tube turns off the CL time, then loops the above action, the signal is given again in the loop, the MOS tube is disconnected, the timing is stopped; the number of cycles (LOP) can be set.
• P3.2: No need to trigger signal after power-on, MOS tube turns on OP time, MOS tube disconnects CL time, loops the above action; loop number (LOP) can be set
• P-4: Signal hold function If there is a trigger signal, the timing is cleared, the MOS transistor remains on; when the signal disappears, the MOS transistor is disconnected after timing the OP; during the timing, there is a signal and the timing is cleared.

Relay Enable Mode:

• ON : MOS tube is allowed to conduct during OP conduction time
• OFF : MOS tube is disabled, always off
• Short press the STOP button on the main interface to switch between ON and OFF. The current state will flash, then return to the main interface. This function is the emergency stop function. One button is used to open and close the MOS tube.
• Sleep mode (long press the stop button to view the current mode)
• C-P sleep mode: within five minutes, without any operation, the digital tube automatically turns off the display, the program runs normally.

Write a review

Please login or register to review